Systematic review2017

Low-level laser therapy for carpal tunnel syndrome

Rankin IA, Sargeant H, Rehman H, Gurusamy KS

The Cochrane database of systematic reviews · 18 citations

Review labels

Funding not disclosed

Neutral facts our review recorded about how this study was done. They describe method, never whether we like the result.

How it was studied

Design
Systematic review (indexed by PubMed)
Studied in
People
Main outcome
Health markers and function

Who paid for it

Funding
Funding not disclosed

Publication

Published
2017-08-22 · Cochrane Database Syst Rev · vol. 2017 · issue 8 · p. CD012765
Publisher
Elsevier BV
Cited
43 citations · more than 86% of similar papers · 2.0× the field average
References
86 works
Access
Open access (repository copy)
Research areas
Peripheral Nerve Disorders · Laser Applications in Dentistry and Medicine · Myofascial pain diagnosis and treatment
Keywords
Medicine, Placebo, Blinding, Transcutaneous electrical nerve stimulation, Confidence interval, Randomized controlled trial, Physical therapy, Carpal tunnel syndrome, Low level laser therapy, Meta-analysis, Clinical trial, Relative risk, Psychological intervention, Surgery, Laser therapy, Internal medicine, Alternative medicine

4 authors

From GB

  • Iain Rankin · correspondingAberdeen Royal Infirmary; NHS Grampian
  • Harry SargeantAberdeen Royal Infirmary; NHS Grampian
  • Haroon RehmanAberdeen Royal Infirmary; NHS Grampian
  • Kurinchi Selvan GurusamyThe Royal Free Hospital; Roland Hill (United Kingdom); University College London

Abstract

Background

The role of low-level laser therapy (LLLT) in the management of carpal tunnel syndrome (CTS) is controversial. While some trials have shown distinct advantages of LLLT over placebo and some other non-surgical treatments, other trials have not.

Objectives

To assess the benefits and harms of LLLT versus placebo and versus other non-surgical interventions in the management of CTS.

Search methods

On 9 December 2016 we searched CENTRAL, MEDLINE, Embase, and Science Citation Index Expanded for randomised controlled trials (RCTs). We also searched clinical trial registries for ongoing studies. We checked the references of primary studies and review articles, and contacted trial authors for additional studies.

Selection criteria

We considered for inclusion RCTs (irrespective of blinding, publication status or language) comparing LLLT versus placebo or non-surgical treatment for the management of CTS.

Data collection and analysis

Two review authors independently identified trials for inclusion and extracted the data. For continuous outcomes, we calculated the mean difference (MD) or standardised mean difference (SMD) with a 95% confidence interval (CI) using the random-effects model, calculated using Review Manager. For dichotomous data, we reported risk ratio (RR) and 95% CI.

Main results

We identified 22 trials randomising 1153 participants that were eligible for inclusion; nine trials (525 participants, 256 randomised to LLLT) compared LLLT with placebo, two (150 participants, 75 randomised to LLLT) compared LLLT with ultrasound, one compared LLLT with placebo and LLLT with ultrasound, two compared LLLT with steroid injection, and one trial each compared LLLT with other non-surgical interventions: fascial manipulation, application of a pulsed magnetic field, transcutaneous electrical nerve stimulation (TENS), steroid injection, tendon gliding exercises, and applying a wrist splint combined with non-steroidal anti-inflammatory drugs. Three studies compared LLLT as part of multiple interventions. Risk of bias varied across the studies, but was high or unclear in most assessed domains in most studies. Most studies were small, with few events, and effect estimates were generally imprecise and inconsistent; the combination of these factors led us to categorise the quality of evidence for most outcomes as very low or, for a small number, low. At short-term follow-up (less than three months), there was very low-quality evidence for any effect over placebo of LLLT on CTS for the primary outcome of Symptom Severity Score (scale 1 to 5, higher score represents worsening; MD -0.36, 95% CI -0.78 to 0.06) or Functional Status Scale (scale 1 to 5, higher score represents worsened disability; MD -0.56, 95% CI -1.03 to -0.09). At short-term (less than three months) follow-up, we are uncertain whether LLLT results in a greater improvement than placebo in visual analogue score (VAS) pain (scale 0 to 10, higher score represents worsening; MD -1.47, 95% CI -2.36 to -0.58) and several aspects of nerve conduction studies (motor nerve latency: higher score represents worsening; MD -0.09 ms, 95% CI -0.16 to -0.03; range 3.1 ms to 4.99 ms; sensory nerve latency: MD -0.10 ms, 95% CI -0.15 to -0.06; range 1.8 ms to 3.9 ms), as the quality of the evidence was very low. When compared with placebo at short-term follow-up, LLLT may slightly improve grip strength (MD 2.58 kg, 95% CI 1.22 to 3.95; range 14.2 kg to 25.23 kg) and finger-pinch strength (MD 0.94 kg, 95% CI 0.43 to 1.44; range 4.35 kg to 5.7 kg); however, the quality of evidence was low. Only VAS pain and finger-pinch strength results reached the minimal clinically important difference (MCID) as previously published. We are uncertain about the effect of LLLT in comparison to ultrasound at short-term follow-up for improvement in VAS pain (MD 2.81, 95% CI 1.21 to 4.40) and motor nerve latency (MD 0.61 ms, 95% CI 0.27 to 0.95), as the quality of evidence was very low. When compared with ultrasound at short-term follow-up, LLLT may result in slightly less improvement in finger-pinch strength (MD -0.71 kg, 95% CI -0.94 to -0.49) and motor nerve amplitude (MD -1.90 mV, 95% CI -3.63 to -0.18; range 7.10 mV to 9.70 mV); however, the quality of evidence was low. There was insufficient evidence to assess the long-term benefits of LLLT versus placebo or ultrasound. There was insufficient evidence to show whether LLLT is better or worse in the management of CTS than other non-surgical interventions. For all outcomes reported within these other comparisons, the quality of evidence was very low. There was insufficient evidence to assess adverse events, as only one study reported this outcome.

Authors' conclusions

The evidence is of very low quality and we found no data to support any clinical effect of LLLT in treating CTS. Only VAS pain and finger-pinch strength met previously published MCIDs but these are likely to be overestimates of effect given the small studies and significant risk of bias. There is low or very low-quality evidence to suggest that LLLT is less effective than ultrasound in the management of CTS based on short-term, clinically significant improvements in pain and finger-pinch strength. There is insufficient evidence to support LLLT being better or worse than any other type of non-surgical treatment in the management of CTS. Any further research of LLLT should be definitive, blinded, and of high quality.

Abstract via Europe PMC. Copyright remains with the authors or publisher.

Community trust

Loading…

How much do you trust this study's findings?

0 · not at all10 · completely

Comments

Sign in to rate, comment on or flag this study.Sign in

Something wrong here?

Flag this study if its information, labels or funding look wrong. An editor reviews every flag.

Sign in to rate, comment on or flag this study.Sign in

Educational information about published research. Not medical advice, and not a recommendation to start or stop anything.